English (United Kingdom)Español (spanish formal Internacional)Deutsch (DE-CH-AT)

Furman Food



AquaClean provided better control of final effluent, reduced BODs and TSS, and lowered odor causing Hydrogen Sulfide. Over time AquaClean continued to drop Hydrogen Sulfide levels, and after three weeks H2S was below 1.0 mg/l.



T.P. ASSOCIATES INTERNATIONAL, INC.
17875 Cherokee P.O. Box 96
Harpster, Ohio 43323
FAX # 614-496-4121
614-496-4571

Mr William E. Lebarre
Environmental & Risk Manager
Furman Foods
R.D. 2
Northumberland, PA 17857

RE: Bio-Augmentation Treatabi1ity Studies
June 8, 1988


Background


The sample received by us on May 26, 1988, was identified as Aeration Contents. This sample was analyzed initially to establish baseline data upon which a treatment comparison could be made. This initial analysis provided us with information concerning the concentrations of nutrients present, and other background data from which an initial dosage rate was calculated.

Following are the results of the ana1ysis:

Laboratory No. M0588-47
Laboratory ID Aeration Contents
pH 7.23 S.U.
Alkalinity 1440 mg/l
T. Suspended Solids 7160 mg/l
Ammonia-N 8.73 mg/l
Phosphorus-P 64.61 mg/l
Zinc 212 ug/l
Sulfide 160 mg/l
COD 18071 mg/l

Experimental


Following this initial analysis, aliquots were inoculated with bacteria at concentrations of 5 and 20 parts per million (PPM). These samples, together with an untreated portion of the sample, which served as a control, were placed into a bio-oxidation system that simulates conditions found in your treatment system. These samples were then monitored over an eight (8) day period. The following is a summary of the results of that monitoring:

Treated @ 5 PPM Treated @ 20 PPM Untreated
05-26-88 18071 7160 160 18071 7160 160 18071 7160 160
05-31-88 893 ---- ---- 496 ---- ---- 2083 ---- ----
06-03-88 968 116 6.40 306 68 4.80 1839 132 76.40
%Red. 94.6% 98.4% 96.0% 98.3% 99% 97% 89.8% 98.1% 52.2%

Conclusions


As can be seen by the above Treatability Study, excellent response to the addition of AquaClean has been observed in your system. The sample treated at 20 PPM showed good response to bio-degradation of the Hydrogen Sulfide and COD. The efficiency of bio-augmentation can be best observed by comparing the results of the untreated portion of the sample with the results of the treated portion of the sample at the same time. In doing this you can see that accelerated bio-degradation was shown to occur in the reduction of the concentrations of COD and TSS. Similarly the response shown to the oxidation of Hydrogen-Sulfide is also dramatically demonstrated by this Treatability Study. The Hydrogen-Sulfide in the untreated portion of the sample was reduced over the period of the study to 76.4 mg/l while the sample treated at 20 PPM indicated a drop to 4.8 mg/l. As the system continues to operate, the Hydrogen-Sulfide levels will continue to drop and should diminish below 1.0 mg/l within the first 15 to 20 days of operation following the initial seeding.

Based on the above Treatability Study, we suggest that AquaClean be considered for use in your system to control the odor produced by the generation of Hydrogen-Sulfide. The organisms of AquaClean will also provide better control of final effluent, BOD and TSS.

We recommend that an initial dosage of 3 to 5 gallons of AquaClean be applied into the equalization tank as an initial seeding. A daily maintenance dose must be applied to your system directly to the influent to the equalization basin. We suggest a dosage of approximately 1 PPM be applied with a metering pump capable of dispensing the material in small incremental amounts throughout the working day. The amount of material used would be approximately one-half to one gallon of AquaClean per week.

It is important to dispense this material on a daily basis as the response, especially to the oxidation of Hydrogen-Sulfide has been shown to increase by as much as 50 to 75 percent over the similar applications on a weekly basis.

Thank you for this opportunity to have demonstrated to you the potential use of bio- augmentation in your system. If you have any questions regarding this report, please do not hesitate to call.

Sincerely
William F. Pfeiffer,Ch.D
Coleen M. Baer Director of Operations Assistant Director


Related Product Information


Waste Water – AquaClean ACF-32

FOG Food Processors, enhancer for ACF-32 - AquaClean ACF / GT