AquaClean: The Effective Solution to FOG and Grease Trap Problems |
|
Where odor represents a problem, especially in food prep areas, select an AquaClean (liquid)
Industrial Series Product and the problem will be solved. Treatment should follow the
following guidelines for in facility use.
- Automatic Pump Applications - Utilizing AQUACLEAN / GT, feed pump with daily
applications of 18 to 21 ounces. Apply AQUACLEAN / GT during low flow periods for
optimum results. For heavy grease loading and systems that require special
attention (historical problems) add an additional quart of AQUACLEAN / ACF-32
monthly to the grease trap, as a grease digester. Make product application by
diluting one quart in one gallon of warm water and distribute to the main drain line
just before the trap.
- Manual Applications - AQUACLEAN / ACF-32 represents our best solution to
general grease problems. Use one gallon to 1 1/2 gallons for each 1.000 to 1,500 of
trap capacity, with product being applied following grease trap pumping. Our
customers advise that as little as one quart of AQUACLEAN / ACF-32 following pumping
eliminates difficult pumping problem WITHIN 30 TO 60 DAYS. It is noteworthy that
they add the product at no charge to eliminate the problems they have in pumping
traps with large grease blocks on the surface. In addition they note that no other
bio-formulation they have tried will provides this result!
- Feed Systems & AQUA-CLEAN - for industrial application and areas where
AQUACLEAN / ACF-32 odor can be accepted, add ACF-32 at 10 ounces per day. For cost
consideration AQUACLEAN / ACF-32 can be diluted 50% with water and applied at 15
ounces per day. Should this method be selected make sure to mix the product well
during blending/dilution.
LINE & TRAP Start Up - review the facilities drain lines and grease traps to determine
if lines and trap should cleaned and pumped prior to biological treatment. In addition
obtain system history regarding line blockages and frequency of trap pumping so a comparison
may be provided on AQUACLEAN product benefits.
For Facility Start-Up - dilute one gallon of AQUACLEAN / ACF-32 with 5 gallon of tap
water, apply 32 ounces of the dilute ACF-32 to each drain line prior to the grease trap
(apply at closing or during a low flow period). This will seed all lines providing odor and
flow benefits in the entire facility as well as benefit the receiving grease trap.
PROBLEM PUMPING - For grease traps with large volumes of solid surface grease (FOG
blocks) add two to three gallons of AQUACLEAN / ACF-32 to the surface of the trap with
enough water to cover the entire surface area. Allow from three to five days to two weeks
for grease liquefaction and then follow up with pumping of the trap and applying AquaClean
as prescribed above for on-going maintenance. |
|